AquaProfiler® stationary
Stationary flow profilers
AquaProfiler® ECM-IE
Stationary Pulse-Doppler system
| Display: | 4 lines, 20 characters |
| Data Logger: | internal, sampling interval user selectable |
| Communication: | RS-232, MODBUS, Ethernet |
| Inputs: | max. 8 x 4-20 mA |
| Outputs: | max. 4 x 4-20 mA 2 x Relay, 2 x Pulse |
| Power Supply: | 85-264 VAC (50-60 Hz) or 12 VDC |
| Approval: | ATEX (option) |
| Enclosure: | Steel, wall mounted |
| Dimensions: | 400 x 500 x 160 mm |
2L
| Frequency: | 2 MHz |
| Max. number of cells: | 64 |
| Max profiling range: | 0,25 to 20 m *) |
| Minimum cell size: | 0,25 m |
| Max blanking: | 0,25 m |
| Range: | velocity ± 8 m/s water level hydrostatic: 0-10 m |
| Temperature Sensor: | -5°C to 40°C |
| Accuracy: | for value v: 0,5% FS ± 0,25 cm/s for value h: 0,1% FS for value t: ± 0,1°C |
| Max. cable length: | 80 m |
| Dimensions: | 350 x 140 x 65 mm |
2XL
| Frequency: | 600 kHz |
| Max. number of cells: | 64 |
| Max profiling range: | 0,5 to 120 m *) |
| Minimum cell size: | 0,5 m |
| Max blanking: | 0,5 m |
| Range: | velocity ± 8 m/s water level hydrostatic: 0-10 m |
| Temperature Sensor: | -5°C to 40°C |
| Accuracy: | for value v: 0,5% FS ± 0,25 cm/s for value h: 0,1% FS for value t: ± 0,1°C |
| Max. cable length: | 80 m |
| Dimensions: | 450 x 140 x 90 mm |