OurProducts
Level Measurement / Open Channel

Ultra 3
Ultra 3 combines several full-function, world-beating ultrasonic level measurement instruments into one. Pulsar engineers have created devices that can be simply configured by the user to provide top-drawer performance. Through the use of ULTRAWIZARD, an integrated high level software configuration tool, you choose your application and the Ultra unit leads you through the set-up process for that specific operation. Full control functions are available: open channel flow is calculated to BS ISO1438 and 4359. Pump control features are built into Ultra3, and an extensive set of volume calculations and linearisation facilities are available for a tank or silo level measurement task.
Ultra 3 features the benefits of DATEM , the world’s most advanced echo processing software, for level measurement.
Ultra 3 in open channel flow mode provides non- contacting, maintenance free flow measurement and control in a wide range of flumes and weirs by calculating flow from the measured head preceding a primary element. Flow calculation to BS ISO 1438 and 4359. Three relays for control choices.
A data logging board is an optional extra, with RS485 together with Profibus DP V0 and V1 or Modbus communications.

Ultra 5
Ultra 5 offers the ultimate flexibility in ultrasonic control and measurement. Like Ultra 3, Ultra 5 is user-configurable to measure level or volume, provide advanced pump control or measure open channel flow to BS ISO 1438 and 4359. Over and above the facilities offered by Ultra 3, Ultra 5 gives you the ultimate flexibility of: five assignable relays with extra alarm options such as pump efficiency; extra pump control functions including pump run-on and pump exercising; storm and aeration control; differential control using two transducers, the addition of further relays in OCM applications.
Ultra 5 features the benefit of DATEM, the world’s most advanced echo processing software, for reliable level measurement.
Open Channel Flow
All the features of the Ultra 3 with 2 additional relays. With the additional step/time control for use with a penstock.
A data logging board is an optional extra with RS485 connection and large data log capability together with Profibus DP V0 and V1 or Modbus communications.

UltraTWIN
Twin-channel ultrasonic level/volume monitoring, pump control, open channel flow measurement or any combination of these.
Flexibility is the keyword for the UltraTWIN 2 channel ultrasonic system.
Each channel is user-configurable to operate independently either as a full function open channel flow monitor calculating flow rate to BS ISO 1438 and 4359, a pump control system or as a level and volume monitoring unit for liquids or solids, calculating set up volumes and providing alarms. UltraTWIN is compatible with the full range of Pulsar’s dB transducers, from the ultra-high resolution dBMACH3 to the powerful 50m range dB50. Six relays configurable to either channel provide full alarm and control options.
Open Channel Flow measurement
When you select the Open Channel Flow option, are getting the full power of Pulsar’s flow measurement expertise, the choice of waste water companies and process industries worldwide to measure open channel flow within effluent treatment processes. Features include on-board totalisation and pulsed output. UltraTWIN provides outstanding accuracy when teamed with the high resolution accuracy of the dBMACH3 transducer.
Latest News

![]()



